How Does Seismic Design Help Project Infrastructure?
October 6, 2026
Seismic design is often treated as a West Coast concern, something California and the Pacific Northwest need to plan for, and the Southeast doesn’t. But in reality, that assumption doesn’t hold up against the region’s actual seismic history, and it can leave commercial buildings, schools, hospital construction, and infrastructure projects underprepared for ground motion they’re not designed to handle.
Seismic design accounts for how a structure responds when ground motion occurs. It applies to new construction and retrofitting older buildings that were never designed with modern seismic codes in mind. Below, we’ll look at what seismic design involves, how seismic design categories work, what retrofitting an older structure typically requires, and how BLE’s geotechnical engineering team supports both new and existing projects across the Southeast.

What is Seismic Design, and Why Does It Matter in the Southeast?
Seismic design is the practice of engineering a structure’s foundation and structural elements to resist the forces generated by ground motion during an earthquake. It draws on geotechnical data about a site’s soil conditions, structural analysis of the building itself, and regional seismic hazard information.
The Southeast, including South Carolina and its neighboring states, sits in an area of moderate to high seismic hazard, and major seismic events have occurred in the region’s history. For example, on August 31, 1886, a magnitude 6.9 to 7.3 earthquake struck near Charleston, South Carolina. It remains one of the most damaging earthquakes ever recorded in the eastern United States, and South Carolina’s Emergency Management Division notes that roughly 70 percent of the state’s earthquakes still occur in the Middleton Place–Summerville Seismic Zone near Charleston. Researchers have also estimated that if a repeat of the 1886 earthquake event occurred today, given how much the region has grown, it could cause hundreds of deaths and billions of dollars in damage.
Because significant earthquakes here are infrequent, it’s easy for property owners and developers to underestimate the risk. That gap between perceived risk and actual seismic hazard is exactly why seismic design deserves attention in this region.

Understanding Seismic Design Categories (SDCs)
Every building subject to the International Building Code (IBC) is assigned a Seismic Design Category, or SDC, ranging from A to F. The SDC determines how rigorous a structure’s seismic design needs to be, and it’s established through a process defined in ASCE 7 and referenced by the IBC.
Two factors drive the outcome:
- Risk Category, which reflects a building’s occupancy and importance. A warehouse, an office building, and a hospital fall into different Risk Categories, with hospitals and other essential facilities held to a higher standard because they need to remain functional after a major event.
- Site-specific ground motion and soil conditions, which come from seismic hazard maps and the seismic site classification. The seismic site classification and SDC are commonly assumed to have the same letter category, but they have different designations most of the time. The same building can land in a lower SDC on a rock site and a higher SDC on soft soil because soft soil amplifies ground shaking.
A building’s SDC shapes which structural systems are permitted, what detailing is required, and whether special inspections apply. It’s the starting point for any seismic design or retrofit project, which is why identifying it early and correctly matters so much.

Seismic Design Considerations for New Construction
For new buildings, seismic design starts well before the first structural drawing. It typically involves:
- Geotechnical site investigation, to characterize soil stiffness, layering, and groundwater conditions during the exploration.
- Liquefaction analysis, to evaluate whether saturated, loose soils could lose strength and behave like a liquid during an earthquake and how foundations will respond to the loss of soil strength.
- Seismic slope stability evaluation, for sites on or near slopes where ground shaking could trigger movement and slope instability.
- Foundation design, sized and detailed to transfer structural loading after a seismic event or to introduce methods to limit liquefaction-induced settlement such as earthquake drains.
- Structural elements such as shear walls and continuous load paths, which give the building a clear route for transferring lateral forces from the roof down to the foundation.
Getting these pieces right the first time is far more straightforward than retrofitting a building after the fact, which is where a large share of the Southeast’s seismic risk actually lives.
Seismic Retrofitting: Bringing Older Buildings Up to Code
Most existing buildings in the Southeast were built before modern seismic provisions were common in local codes. That means many structures, especially older commercial buildings and homes, weren’t designed to resist seismic forces at all.
Two structural weaknesses show up often in retrofit assessments:
- Soft story conditions, where a ground floor has large openings, such as a row of garage doors, storefronts, or parking, and lacks enough wall area to resist lateral forces the way the floors above it can. This creates a weak point where a building’s structure can concentrate damage during an earthquake.
- Cripple walls are the short wood-frame walls that sit between a foundation and the first floor in many older homes. When they’re not braced, they can shift or collapse under lateral load.
Retrofitting addresses these weaknesses with a combination of techniques, chosen based on the structure and its deficiencies. These can include:
- Shear walls, added or reinforced to give the structure a stronger path for resisting lateral forces
- Anchor bolts, which tie the wood framing of a building securely to its foundation
- Cripple wall bracing, to stiffen and strengthen these vulnerable short walls
- Fiber-reinforced polymer (FRP) wrapping, used on concrete or masonry columns and walls to improve their strength and ductility without adding significant weight
The retrofitting process generally starts with a structural evaluation to identify a building’s specific deficiencies, followed by an engineered design and then construction. The scope can range from a straightforward foundation bolting project on a single building to a more involved soft-story retrofit on a larger commercial structure.

What Happens When Seismic Risk Is Overlooked
Skipping seismic design or retrofit work can leave serious risks unaddressed, opening the door to consequences later down the road. These may include:
- Structural damage or collapse during a seismic event, particularly at soft-story or cripple wall weak points
- Code non-compliance, which can complicate permitting, financing, and insurance coverage
- Elevated exposure for essential facilities, hospitals, schools, and emergency operations centers, which are expected to keep functioning immediately after a major event, not just avoid collapse after a seismic event
For property owners and developers in the Southeast, the combination of underestimated risk and older building stock makes this a real gap worth closing, not a distant concern.
How BLE Supports Seismic Design and Retrofit Projects
As seismic design consultants, BLE’s geotechnical engineering team works with developers, structural engineers, and facility owners across the Southeast on both new construction and existing structures. Our seismic-related services include:
- Seismic risk assessments
- Liquefaction analysis
- Seismic slope stability evaluations
We support commercial, institutional, infrastructure, and transportation projects throughout the region, working alongside structural engineers and architects to make sure a project’s seismic site classification, site conditions, foundation design, and liquefaction mitigation measures align from the start. For existing buildings, our team can work with structural engineers to provide the geotechnical analysis needed to inform a retrofit design.

Build and Retrofit with Seismic Risk in Mind
Seismic risk in the Southeast is easy to underestimate and expensive to ignore. Whether you’re planning new construction or evaluating an older building for retrofit work, understanding your Seismic Design Category and site conditions is the place to start.
Contact BLE to discuss seismic risk assessment and design solutions for your next project – new construction or existing structure.
What is a Seismic Design Category, and how is mine determined?
A Seismic Design Category is a letter grade, A through F, that sets the seismic design requirements for a building. It’s based on the building’s Risk Category (tied to its occupancy) and the ground motion and soil conditions at the specific site. This is not the same as the seismic site classification, which is commonly provided in a geotechnical report. The structural engineer will provide the SDC based on the requirements in the IBC and the seismic site classification provided.
Does the Southeast really have earthquake risk?
Yes. South Carolina and its neighboring states sit in an area of moderate to high seismic hazard, and the region experienced one of the most damaging earthquakes in U.S. history near Charleston in 1886.
How do I know if my building needs seismic retrofitting?
Older buildings with soft-story conditions, unbraced cripple walls, or construction that predates modern seismic codes are common candidates. A structural evaluation is the best way to identify specific deficiencies.
What’s the difference between seismic design and seismic retrofitting?
Seismic design applies to new construction, building in seismic resistance from the ground up. Seismic retrofitting applies to existing buildings, adding or reinforcing structural elements to bring an older structure closer to current seismic standards.